New issues - Известия Казанского государственного архитектурно-строительного университета.

Включен в Перечень ведущих рецензируемых научных журналов и изданий, определяемый ВАК

New issues

About the authors



First name, Middle name, Last name, Scientific degree, Scientific rank, Current position. Full and brief name of the organization, The organization address.Alexey V. Busakhin, candidate of technical sciences, associate professor, National Research Moscow State University of Civil Engineering, Moscow, Russian Federation Email: This e-mail address is being protected from spambots. You need JavaScript enabled to view it , ORCID: 0000-0001-7373-5612 Georgii A. Savenko, lecturer, National Research Moscow State University of Civil Engineering, Moscow, Russian Federation Email: This e-mail address is being protected from spambots. You need JavaScript enabled to view it , ORCID: 0009-0004-1982-4824
Title of the articleDevelopment of the operation mode of the smoke ventilation system in the inter-apartment corridor
Abstract.The relevance of the research is due to the intensive development of high-rise construction. The traditional design of smoke ventilation often does not take into account the dynamics of the fire and the interaction of smoke extraction and compensation systems. According to the Ministry of Emergency Situations of Russia over a 5-year period, 68% of fires in apartment buildings are accompanied by critical smoke on evacuation routes, especially in buildings with open-plan layouts. Problem statement. The study is aimed at evaluating the effectiveness of solutions for smoke ventilation systems in conditions of fire development using the example of a 26-storey residential complex. The purpose is to analyze the interaction of smoke extraction and air compensation systems in inter-apartment corridors at the stage of fire power growth and to develop a methodology for evaluating the effectiveness of fire control during its unsteady development. Research objectives: based on a normative methodology, calculate the power of the fire source and the growing oxygen consumption, taking into account the parameters of the room and the fire load. The mass and volume consumption of the burning products being removed, their temperature and density were determined. The development time of the fire source (30 minutes to peak power) and the flame spread have been calculated. Results show, that smoke ventilation systems that provide a volumetric balance between the removal of the smoke and gas mixture and the supply of compensation air prevent excessive underpressure at the doors (pressure drop 150 Pa). In 30 minutes, the fire load burns out by 50%, while the volume of compensation air does not exceed critical values capable of stimulating the development of the fire. Conclusions. A calculated approach to the design of smoke ventilation, which ensures a volumetric balance, increases the safety of evacuation and complies with regulatory requirements. The results are relevant for apartment buildings, where the correct operation of systems is critical to minimize risks. The study confirms the need to take into account the dynamics of fire and the interaction of ventilation systems.
Keywords.smoke ventilation, time of fire development, air mode, evacuation, safety
For citations:Busakhin A.V., Savenko G.A. Development of the operation mode of the smoke ventilation system in the inter-apartment corridor // News of KSUAE, 2025, № 3(73), p. 103-114, DOI: 10.48612/NewsKSUAE/73.9, EDN: JCDKEC


New issues

 
Russian (CIS)English (United Kingdom)

Login

Search

Vinaora Visitors Counter

mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday111
mod_vvisit_counterYesterday129
mod_vvisit_counterThis week888
mod_vvisit_counterLast week908
mod_vvisit_counterThis month2801
mod_vvisit_counterLast month3720
mod_vvisit_counterAll days829613

Online (12 hours ago): 2
Your IP: 192.168.1.44
MOZILLA 5.0,
Today: Ноя 22, 2025