First name, Middle name, Last name, Scientific degree, Scientific rank, Current position. Full and brief name of the organization, The organization address.Smirnov D.S. – candidate of technical science, associate professor E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it Kamalova Z.A. – candidate of technical science, associate professor Rachimov R.Z. – doctor of technical science, professor E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it Kazan State University of Architecture and Engineering The organization address: 420043, Russia, Kazan, Zelenaya st., 1
Title of the articleAssessment of corrosion resistance of the steel armature in a modified concrete
Abstract.Despite the decline in the production of concrete caused by the global economic crisis, remains the most popular building material and concrete structures are the basis of modern industrial structural and civil engineering. From other building materials he has process ability, good mechanical properties and durability. Improved properties of concrete can be used modifiers. However, in this case, some of the additives used may have a negative impact on the steel of reinforcement. This article presents the results of testing the corrosion resistance of reinforcement in concrete containing additives «Plast», production company «HimFrost», that reduce water consumption in concrete. According to the obtained results, plasticizer «PLAST» has no adverse effects on the corrosion of reinforcement in concrete. Weight loss for samples of reinforcement in concrete without additives after 180 days amounted 9,1356 gr/m2, and in the concrete with the additive 9,3878 gr/m2. For both samples, the results of the test match the requirements of GOST R 52804-2007 and does not exceed 10 g/m2. Higher loss of mass of the samples reinforcement in the concrete with the additive «PLAST» is obviously connected with the fact that when plasticization is released water, which further leads to the redistribution of porosity increase of capillary pores, and this, in turn, increases the permeability of concrete.
Keywords.Reinforced concrete, steel, corrosion of armature, durability of concrete structures, corrosion testing.
For citations:Smirnov D.S., Kamalova Z.A., Rachimov R.Z. Assessment of corrosion resistance of the steel armature in a modified concrete // Izvestiya KGASU. 2014. №3(29) P.133-139.


New issues

 
Russian (CIS)English (United Kingdom)

Search

Vinaora Visitors Counter

mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday56
mod_vvisit_counterYesterday95
mod_vvisit_counterThis week265
mod_vvisit_counterLast week680
mod_vvisit_counterThis month1903
mod_vvisit_counterLast month777
mod_vvisit_counterAll days773246

Online (12 hours ago): 2
Your IP: 192.168.1.44
MOZILLA 5.0,
Today: Апр 23, 2024