Archive - Известия Казанского государственного архитектурно-строительного университета.

Включен в Перечень ведущих рецензируемых научных журналов и изданий, определяемый ВАК

Archive

About the authors



First name, Middle name, Last name, Scientific degree, Scientific rank, Current position. Full and brief name of the organization, The organization address.Kamalova Z.A. – candidate of technical science, professor Smirnov D.S. – candidate of technical science, associate professor Е-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it Rachimov R.Z. – doctor of technical science, professor Kazan State University of Architecture and Engineering The organization address: 420043, Kazan, Zelenaya st., 1
Title of the articleThermal resistance of walls with insulation materials loose on the basis of sawdust
Abstract.The article describes the experience of the problems of energy saving buildings and structures through the use of effective thermal insulation materials in the country and abroad. The authors of the articles are designed compositions of bulk materials based on filings with the addition of gypsum, lime and antiseptic ingredients. The resulting heat-insulating material is rot and caking, inexpensive, easy to manufacture and environmentally safe. The main area of its possible applications are low-rise buildings frame type, as structural elements of the framework that use metal or wood. In this paper we present a calculation of the Thermal walling using material developed by the optimum composition. Thermal calculation includes the determination of thickness of the insulation layer. Design exterior fences built on the principles of limiting the amount of heat lost by the enclosure during the heating season and to maintain the inner surface of the outer enclosure temperature at which the inner surface of no condensation. This paper presents a technical solution design exterior walls. The calculation of steady-state temperature field in the enclosure. A limitation of temperature and moisture condensation on the inner surface of the cladding. Calculated moisture conditions walling. Checking the cladding on the air permeability showed that it meets the requirements. As a result of the calculations indicated that the application of the developed material as an insulator in protecting designs can provide all the thermal performance of the building with wall thickness not exceeding 26 cm.
Keywords.Loose insulation, wood chips, thermal conductivity, building envelope, heat engineering calculations.
For citations:Kamalova Z.A., Smirnov D.S., Rachimov R.Z. Thermal resistance of walls with insulation materials loose on the basis of sawdust // Izvestiya KGASU. 2012. №1(19) P.103-109.


New issues

 
Russian (CIS)English (United Kingdom)

Search

Vinaora Visitors Counter

mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday101
mod_vvisit_counterYesterday117
mod_vvisit_counterThis week613
mod_vvisit_counterLast week680
mod_vvisit_counterThis month2251
mod_vvisit_counterLast month777
mod_vvisit_counterAll days773594

Online (12 hours ago): 2
Your IP: 192.168.1.44
MOZILLA 5.0,
Today: Апр 26, 2024