First name, Middle name, Last name, Scientific degree, Scientific rank, Current position. Full and brief name of the organization, The organization address.Khuziakhmetov R.A. – candidate of technical sciences, associate professor E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it Sharapova N.B. – student E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it Kazan State University of Architecture and Engineering The organization address: 420043, Russia, Kazan, Zelenaya st., 1
Title of the articleInformational analysis of normative safety requirements and natural research of a condition of networks of power supply and system of grounding residential building after reconstruction
Abstract.The problem of ensuring the safety of human existence is to discharge all the major countries of the world. In the Russian Federation realization of priority tasks of ensuring the safety of human existence, his life laid down in the Constitution of the Russian Federation and supported by the active introduction of a number of federal laws technical content, and the development in the direction of human security and the environment. However, the obvious is the fact that the level of financing of security measures in general, determined by the economic condition of the country. In this regard, we can say that in solving the problem raising the level of electrical safety in residential buildings must be taken not the pioneer solutions that are at once instantly qualitatively raise the bar of safety. Even the translation of electric networks to the grounding system TN-C voltage 380/220 V with earthing system TN-S or TN-C-S in any region of the country, I think, is a task almost impossible. This follows from the fact that the residential development of forty-fifty years ago provided nets to the grounding system TN-C, which are now in need of at least a complete redesign. Difficulties in ensuring the electrical safety in the homes of old buildings, are predetermined by the fact that when the overhaul of the building for the supply of electricity to consumers takes you to the network earthing system TN-C-S, and the wiring installation in apartments, made earlier in the construction of the building remains in the old version for network grounding system TN-C.
Keywords.electric current, electrical safety, TN, TN-C, TN-S, TN-C-S systems, electrodefeat, grounding.
For citations:Khuziakhmetov R.A., Sharapova N.B. Informational analysis of normative safety requirements and natural research of a condition of networks of power supply and system of grounding residential building after reconstruction // Izvestiya KGASU. 2015. №4(34) P.339-344.


New issues

 
Russian (CIS)English (United Kingdom)

Search

Vinaora Visitors Counter

mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday77
mod_vvisit_counterYesterday61
mod_vvisit_counterThis week251
mod_vvisit_counterLast week653
mod_vvisit_counterThis month251
mod_vvisit_counterLast month2858
mod_vvisit_counterAll days792961

Online (12 hours ago): 2
Your IP: 192.168.1.44
MOZILLA 5.0,
Today: Дек 04, 2024