Archive - Известия Казанского государственного архитектурно-строительного университета.

Включен в Перечень ведущих рецензируемых научных журналов и изданий, определяемый ВАК

Archive

About the authors



First name, Middle name, Last name, Scientific degree, Scientific rank, Current position. Full and brief name of the organization, The organization address.Ivan O. Stepanov, engineer, State Unitary Enterprise of The Republic of Tatarstan "Head Territorial Design and Survey Research and Production Firm "Tatinvestgrazhdanproekt", Kazan, Russian Federation E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it , ORCID: 0009-0001-0637-9053 Dmitriy V. Kraynov, candidate of technical sciences, associate professor, Kazan State University of Architecture and Engineering, Kazan, Russian Federation E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it , ORCID: 0000-0003-3074-9090
Title of the articleApplication of a digital twin for indoor microclimate monitoring
Abstract.Problem statement. Information modeling technology is actively used at the design and construction stage, generating a large amount of information about the facility. At the operational stage, this information is almost not used, although operational services need it to make effective decisions, which is the reason for special attention to this topic. The purpose of the research is to develop a digital twin for monitoring the microclimate in the premises of the scientific and educational center “Systems”, located on the campus of Kazan State University of Architecture and Engineering. To achieve this goal, the following tasks are formulated: to analyze the possibility of using digital twin technology at the stage of operation of a building for a selected facility, to develop a measuring tool and a method for transmitting data on temperature and humidity of internal air to the information model of the classroom. Results. Using the example of a classroom at the scientific and educational center “Systems”, a method for monitoring indoor microclimate parameters with data transfer to a digital information model of the building in real time has been developed. The novelty of the results lies in the improvement of the process of operating buildings in order to ensure a comfortable indoor microclimate. For the construction industry, there is an opportunity to optimize costs while ensuring a comfortable microclimate using a digital building information model.
Keywords.Digital twin, building operation, information modeling technology, BIM, Internet of things, MQTT protocol
For citations:Stepanov I.O., Kraynov D.V. Application of a digital twin for indoor microclimate monitoring // News KSUAE, 2024, № 2(68), p. 26-36, DOI: 10.48612/NewsKSUAE/68.3, EDN: CQRTXM


New issues

 
Russian (CIS)English (United Kingdom)

Search

Vinaora Visitors Counter

mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday46
mod_vvisit_counterYesterday95
mod_vvisit_counterThis week404
mod_vvisit_counterLast week680
mod_vvisit_counterThis month1971
mod_vvisit_counterLast month2890
mod_vvisit_counterAll days791823

Online (12 hours ago): 2
Your IP: 192.168.1.44
MOZILLA 5.0,
Today: Ноя 21, 2024